T. Jhansi, D. Kumar, Nagaraju Rajana
Nov 30, 2019
Citations
0
Influential Citations
1
Citations
Journal
Asian Journal of Chemistry
Abstract
A reverse phase chiral HPLC method was developed for the determination of (R)-2-aminobutanamide isomer content in (S)-2-amino-butanamide key starting material for levetiracetam drug substance by using a CROWNPAK CR (+) column. Perchloric acid solution (0.05 %) was used as mobile phase and the flow rate was finalized as 0.3 mL/min. UV detection wavelength was 200 nm and column temperature was set as 15 ºC. The limit of detection and limit of quantification were 0.0002 mg/mL and 0.0005 mg/mL, respectively. The linearity calibration curve of (R)-2-aminobutanamide was shown good from the range of 0.0005 mg/mL to 0.004 mg/mL. The recovery of (R)-2-aminobutanamide isomer was between the range of 93 to 106 % in presence of (S)-2-aminobutanamide. The method was validated and found to be precise, accurate and robust. The method can be used for determination of (R)-2-aminobutanamide in presence of (S)-2-aminobutanamide, which is the key intermediate for preparation of levetiracetam. This method was validated in as per ICH Q2 (R1) and USP validation of compendial methods (1225).