A. Schepdael, R. Kibaya, E. Roets
Sep 1, 1995
Citations
1
Influential Citations
31
Citations
Journal
Chromatographia
Abstract
SummaryDoxycycline is a semi-synthetic broad spectrum antibiotic with improved serum half-lie. Potential impurities are 4-epidoxycycline, 6-epidoxycycline, 4,6-epidoxycycline, metacycline and 2-acetyl-2-decarboxamidodoxycycline. Method development has been undertaken to investigate the potential of capillary electrophoresis for the analysis of doxycycline. The influence of buffer type, buffer pH and concentration was systematically examined, then that of capillary temperature and applied voltage. All the potential impurities could be separated at 15 °C on a 44 cm × 50 µm I.D. fused silica capillary (effective length to detector, 38 cm) with sodium carbonate (70 mM) - EDTA (1 mM), pH 10.50, as background electrolyte and with a voltage of 12 kV. The relative standard deviation was 2.2 % for doxycycline. The limit of detection and quantification for doxycycline were 0.2 and 0.4 %.