E. Leibrock, L. G. Huey
Jun 15, 2000
Citations
0
Influential Citations
25
Citations
Journal
Geophysical Research Letters
Abstract
A chemical ionization mass spectrometer (CIMS) and a flowing afterglow apparatus were used to study reactions of benzene cations (C6H6+ and (C6H6)2+) with a series of volatile organic compounds (VOCs). Both cations react at the collision rate with compounds of lower ionization potential than benzene, such as isoprene (C5H8), other conjugated dienes, and aromatics. These ions are generally unreactive with substances of higher ionization potential such as alkanes, simple alcohols, simple carbonyls, etc. The results demonstrate that C6H6+ and (C6H6)2+ are excellent reagent ions for the sensitive detection of isoprene in air with a CIMS. However, 2‐methyl‐3‐buten‐2‐ol (MBO) and C5H8 conjugated dienes were identified as potential interferences to this technique. This indicates that the selectivity of the CIMS isoprene measurement must be tested by intercomparison with well‐established methods, e.g. gas chromatography techniques.