W. Wargniez, Elsa Jungman, S. Wilkinson
Aug 15, 2017
Citations
0
Influential Citations
10
Citations
Journal
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
Abstract
In the present study, three laboratories independently compared percutaneous absorption and distribution of 4-n-butylresorcinol, using human skin from five donors. Each laboratory used the same protocol for percutaneous absorption studies but different LC-MS/MS analytical methods to quantify the test compound. All laboratories respected the mass balance criteria (i.e. 100±15%; average 96.5-102% of applied dose). Regarding usual inter-lab variability, good agreement was observed for all compartments with the greatest difference in the epidermis: 3.3 fold increase. The data obtained demonstrate that robustness of skin absorption data rely on properly validated analytical methods including sample extraction and LC-MS/MS method. It also includes clearly defined cutaneous absorption protocol for dose skin preparation, application, washing and tape stripping.