V. Patcha, Susheela Bhai Gajbhiye, U. Ray
Apr 8, 2018
Citations
0
Influential Citations
0
Citations
Journal
Journal name not available for this finding
Abstract
A sensitive and rapid HPLC method developed and validated for the determination of potential genotoxic impurity namely m-aminobenzoic acid at trace level in Ertapenem monosodium by applying the concept of threshold of toxicological concern (TTC). The HPLC method was developed and optimized on Inertsil ODS-3V, 250 mm × 4.6 mm, 5m column with oven temperature maintaining at 40°C. 0.02M Sodium Phosphate buffer pH 2.5 was chosen as mobile phase A and methanol was selected as mobile phase B in gradient reverse phase mode. Chromatographic parameters i.e flow rate: 1.0 ml/min, wavelength detection: 220 nm, injection volume: 10μl and run time: 20 min were applied in this methodology. Based on validation data, the method is found to be specific, sensitive, accurate and precise. The established limits of Limit of detection and Limit of quantification for this impurity are found to be 3.9 μg/g and 11.9 μg/g respectively. The average recovery obtained was 99.8% at four levels in twelve determinations for m-aminobenzoic acid in Ertapenem monosodium drug substance. This method can be used as good quality control tool for quantization of m-aminobenzoic acid at low level. The experimental results are discussed in detail in this research paper.